Description

The CBGj2100 gear pump is listed in the wheel loader parts catalog under that reference. Use the exact label from the installed pump when requesting a quotation. The supplier needs to see which housing and any sections or covers are in scope, as well as the drive interface and connections. The catalog title alone does not supply a displacement, operating pressure, rotation direction or a confirmed loader model.

Part identification before ordering
Catalog codeCBGj2100
Search variationCBGJ2100 is a capitalization variation for lookup
Identify the buildFull installed label, housing and cover layout, number of sections and port locations
Verify the driveDrive flange, coupling or shaft and manufacturer drawing
Confirm scopeComplete configured pump versus referenced individual components

Start by documenting what the work order calls a pump

When a shop lists a pump for replacement, the removed unit may have a cover, attached adapter or additional section that is also part of the assembly it expects to receive. Lay out the requested scope with a picture showing the full unit end to end. Make close-up images after that overview. A picture of the label on its own is easy to detach from the shape and interfaces to which it belongs. Put the machine and work order number in the file labels so later photos do not become mixed with another pump.

If there is more than one section, identify how many are actually present. Use numbered photo labels running from the drive end to the opposite end. Mark every identifiable connection in the picture and send a machine diagram that shows what each connection serves. This information allows a supplier to compare what is fitted without treating the shape of the housing alone as proof of the internal configuration.

When an old label and a quotation use different capitalization

Keep a photograph of the original code even if a distributor writes it all in uppercase. That change can be innocent, but omitted letters or suffixes should be resolved. Ask for the maker's complete designation of the offered unit and compare the two references side by side. Where the label includes a second line or plate code, send it as a separate value. It may describe the build or manufacturing series and help the supplier explain why the quotation adds a suffix.

A supplier should be able to state which document or item marking supports a cross-reference. Record the approval alongside the quoted part number instead of shortening both names to “CBG pump” in inventory. In a fleet with several similar pumps, the abbreviated stock description makes it difficult for the next buyer to see which assembly the earlier job used. Retain the designation exactly as received, while searchable variations can go in the comments.

Draw the assembly as the technician sees it

A useful workshop sketch identifies the shaft side, the mounting flange and the face where each connection sits. If a line leaves a cover or intermediate block, name that cover separately. A photo of a fully plumbed pump can hide the body ports behind the fittings. Record which pieces of hardware were installed with the pump and which pieces traveled with it when it was removed. This helps the purchasing team ask for a replacement with the same scope.

Send both an end view and a side view of cleaned external features when the technician can do so. If a separate component looks like part of the pump in a distant photo, capture the joint between them. When a quote asks whether a mounting adapter is required, these photos save the technician from opening the parts again just to establish a boundary. The quote can then list the pump, optional hardware and any verified accessory separately.

If there are two possible pumps in the machine file

Some workshop files contain records of an earlier repair or an exchange assembly. Compare the photographs of the installed tag and flange against both records. Ask which machine serial and configuration each invoice covered. A supplier can then quote a single identified assembly, or describe the remaining question if the installed part cannot be confirmed. An unverified earlier fit in a similar loader is a lead for a comparison, not a standing interchange approval.

The CB-FE40FL gear pump listing is another pump reference in our catalog. Compare the labels and build data before deciding between similar-looking product pages. The Shantui wheel loader parts category also contains other drivetrain and hydraulic entries if a work order calls for several independent components.

Verify the contents when the crate is opened

Check that the nameplate, number of sections and visible housing interfaces match the approved quote. If a protective flange cover prevents a measurement, keep that fact on the receiving sheet for the technician. Make a record of attached hardware and loose hardware separately. If the supplied build code is different, obtain the approved interchange reference before assigning the pump to its repair job. One receiving photo of the whole unopened package seldom captures enough to show which parts came with it.

Keep the final approved documents accessible to the mechanic. A verified parts match identifies the pump and the inclusion list. Operating checks and any preparation for starting the system come from the service literature for the installed assembly.

A stocked pump can sit through several rounds of equipment changes. Before treating a spare from the shelf as the answer to a breakdown, retrieve the order record and compare its section arrangement with the installed unit. Make a new photo of the stored label if the record only contains a typed reference. Attached items sometimes move between bins or are recorded under a separate workshop number. Record explicitly whether an adapter from the old machine is expected to carry over, and make sure the fitter has the corresponding drawing. If the system drawing is not available, keep that uncertainty in the repair note rather than quietly treating the spare as an approved replacement. A later buyer will then know which comparison still needs to be made.

Frequently asked questions

Is CBGJ2100 the same search as CBGj2100?

It can locate the same catalog name when only capitalization differs. Confirm the complete label and build option with the supplier before treating the names as an exact match. Punctuation, suffixes and secondary markings may still matter.

How do I order a pump when the original has multiple sections?

Record the section count and show the full unit from the drive end onward. Mark port locations and any separate adapters. Ask the supplier to quote the configured assembly and to name the sections and attachments it includes.

Can I infer pump capacity from the name on this page?

Use the machine requirement and the specification for the exact pump offered. The catalog provides a search reference. Request the data sheet for the offered build and confirm it with the workshop.

FREE Inquiry Now

If you have any questions, feedback or comments, please fill out the form below and we will reply you back as soon as possible.

+86-130-4508-1859